owner's manual
MODEL NOS:
1403612; 1403622
2203612; 2203622
3003612; 3003622
FOR USE WITH
NATURAL GAS ONLY
f-
_/ APPROVED
®
M()DEL NOS.
1403611; 1403621
2203611 ; 2203621
3003611 ; 3003621
FOR USE WITH
LIQUEFIED
PETROLEUM (L.P.)
GAS ONLY
0tSlG,
GRAVITY DIRECT VENT
FURNACE
READ THIS OWNERS
MANUAL CAREFULLY
BEFORE YOU INSTALL
YOUR NEW WILLIAMS
WALL FURNACE
Unpacking
Installation
Operation
Repair Parts
-- MODEL NUMBER INFORMATION --
NOTE: CANADIAN MODEL NUMBERS THIRD
DIGIT FROM LEFT TO BE:
1 FOR BASIC ALTITUDE
2 FOR HIGH ALTITUDE
EXAMPLE:
MODEL: 1403612 BECOMES 1413612
(0-2000 FT. BASIC ALTITUDE)
OR BECOMES 1423612
(2000-4000- FT. HIGH ALTITUDE)
WARNING: Improper installation, adjust-
ment, alteration, service or maintenance
can cause injury or property damage.
Refer to this manual. For assistance or
additional information consult a qualified
installer, service agency or the gas
supplier.
WARNING: Do not install any of these fur-
naces (Natural or L.R Gas) in mobile
homes, trailers, or recreational vehicles.
WARNING: If the information in this
manual is not followed exactly, a fire or ex-
plosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Open all windows.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Extinguish any open flame.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instruction.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
WILLIAMS Furnace Co., 225 Acacia St., Colton, CA 92324
PRINTED IN USA 5/97 P322256
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - GRAVITY DIRECT VENT

owner's manualMODEL NOS:1403612; 14036222203612; 22036223003612; 3003622FOR USE WITHNATURAL GAS ONLYf-_/ APPROVED®M()DEL NOS.1403611; 14036212203

Page 2 - Your Warranty

Gas Supply & PipingGas control valve, within the furnace, is shipped with aseal over gas inlet tapping. Do not remove this seal untilready to conn

Page 3 - Optional Accessories

Gas Supply & Piping (cont.)GAS PtPE SIZESNATURAL GASPIPE CAPACITY - BTU PER HOUR(INCLUDES FITTINGS)PIPE SIZELENGTH OFPIPE - FEET 1/2 inch 3/4 inch

Page 4 - Safety Rules

Thermostat Installation (cont.)6. Snag thermostat cable through wall so that 6 inchesof cable protrudes.7. Route cable to wall furnace leaving enough

Page 5 - Installing Your Wall Furnace

Furnace Technical InformationMODEl. TYPE INPUT *NUIBMm GAS RATINGIrTU/NR1403612 NAT. 14,0001403611 L.P.G. 14,0001403622 NAT. 14,0001403621 LP.G. 14,00

Page 6 - Locating Wall Furnace

Start-Up ProcedureStart the furnace using the procedures in sectionOperating Your Furnace on pages 15 through 19.WARNINGDANGER OF BODILY INJURY OR DEA

Page 7 - Installation

Operating Your FurnaceBUILT-IN THERMOSTAT MODELS 1403611, 1403612,2203611, 2203612, 3003611 and 3003612Refer to this sheet and sheet 16 (or) 17 for &q

Page 8 - Installation (cont.)

FOR YOUR SAFETY, READ BEFORE LIGHTINGWILLIAMS GAS CONTROL VALVE P322053 & P322054I WARNING: If you do not follow these instructions exactly, a fir

Page 9 - ,,,..-...,-,.I ;

A.B.FOR YOUR SAFETY, READ BEFORE LIGHTINGWILLIAMS GAS CONTROL VALVE P295300A & P295301AI WARNING: If you do not follow these instructions exactly,

Page 10 - Gas Supply & Piping

FOR YOUR SAFETY, READ BEFORE LIGHTINGWILLIAMS GAS CONTROL VALVE P121200 & P171600I WARNING: If you do not follow these instructions exactly, a fir

Page 11 - Thermostat Installation

A.B.FOR YOUR SAFETY, READ BEFORE LIGHTINGWILLIAMS GAS CONTROL VALVE P295200A & P295201AI WARNING: If you do not follow these instructions exactly,

Page 12 - JOINT UNION

ContentsYour Warranty ... 2Introduction ... 3Basic Description ...

Page 13 - #51 0670

How To Care For Your FurnaceMAINTENANCEIt is recommended that a competent serviceman performthese checks at the beginning of each heating season:a. Bu

Page 14 - Start-Up Procedure

Troubleshooting Gravity Direct Vent Wall FurnaceSYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION1. Pilot will not stay lit aftercarefully followinglighting in

Page 15 - Operating Your Furnace

Troubleshooting ... (cont.)SYMPTOM4, Furnace operates butturns "Off" before roomtemperature is attained.5. Furnace not producingsufficient h

Page 16 - I_ _ e! ot / Hoe _owN

Williams Direct Vent Gas-Fired Wail FurnaceREPLACEMENT PARTS FOROPTIONAL BLOWER ACCESSORY 2302MODELS: 2205611; 2205612; 2205621; 22056225005611; 50056

Page 17 - TO TURN OFF GAS TO APPLIANCE

Williams Direct Vent Gas-Fired Wall FurnaceREPLACEMENT PARTS FOR MODELS:1403611; 1403612; 1403621; 1403622REF.NO.12345678910111213PART NO. DESCRIPTION

Page 18 - LAc ,-,I

Williams Direct Vent Gas-Fired Wall FurnaceREPLACEMENT PARTSFOR MODELS:1403611 ; 140361 21403621 ; 1403622FOR PARTS lISTING SEE PAGE 24.USE ONLY MANUF

Page 19 - OPERATING INSTRUCTIONS

owner'smanualSERVICEMODEL NOS.1403612 NAT1403622 NAT2203612 NAT2203622 NAT3003612 NAT3003622 NAT1403611 LPG1403621LPG2203611LPG2203621LPG3003611L

Page 20 - 1111111111Ill/llll/tlltl

IntroductionPlease read our instructions before you install and use your furnace. This will help you obtain the full value from thisfurnace. It could

Page 21

Safety RulesWARNINGREAD THESE RULES AND THE INSTRUCTIONSCAREFULLY. FAILURE TO FOLLOW THESERULES AND INSTRUCTIONS COULD CAUSE AMALFUNCTION OFTHE FURNAC

Page 22 - Troubleshooting ... (cont.)

Unpack Your FurnaceThis direct-vent furnace is packaged complete includingthe vent cap, vent tube and air inlet tube ready for instal-lation on an ext

Page 23 - REPLACEMENT PARTS FOR

Locating Wall FurnaceConsider the following points before attempting to installthe furnace:ALL MODELS1. This is a direct vent wall furnace. It must be

Page 24 - REPLACEMENT PARTS FOR MODELS:

Locating Wall Furnace (cont.)MODELS 1403622, 1403621, 2203622, 2203621,3003622 and 3003621(All other models have a built-in thermostat)Choose a locati

Page 25 - 1403621 ; 1403622

Installation (cont.)GAS AND ELECTRICAL SUPPLY OPENINGSHoles must be drilled for the gas line (and electricalsupply if you use an optional Blower Kit).

Page 26 - How to Order Repair Parts

Installation (cont.)INSTALL VENT CAPOutside, place a single strip of mastic (provided) aroundthe back flange of the vent cap ("G" Fig. 5, pa